Cuba Cross-flow cooling tower

Cross-flow closed cooling towers are suitable for medium to large-scale cooling needs, and are especially suitable for applications that need to keep the water clean. They perform well in hot climates because they can use the cooling effect of outside air without requiring large amounts of water. They are usually used to cool hot water or cooling media in large facilities such as factories, power plants, chemical plants, refineries, steel plants, etc.

Category:

Product Description

Scope of application

Cross-flow closed cooling towers are suitable for medium to large-scale cooling needs, and are especially suitable for applications that need to keep the water clean. They perform well in hot climates because they can use the cooling effect of outside air without requiring large amounts of water. They are usually used to cool hot water or cooling media in large facilities such as factories, power plants, chemical plants, refineries, steel plants, etc.

Product Features

Construction, installation and maintenance is easy, low cost, commonly used in air conditioning and industrial large and medium-sized cooling circulating water.  
Commonly used in residential areas with strict noise requirements, is the air conditioning industry to use more cooling cycle tower.  
Energy saving, low water pressure, small wind resistance, also equipped with low-speed motor, no dripping noise and wind noise, filling and water distribution system maintenance is convenient.
 

ML-FBFH composite flow-related parameters

Model

tonnage

Overall dimension

Fan parameters

Spray pump parameters

Inlet and outlet pipe diameter

Cooling tower

Length × width × height

Number of fans

Power

Air volume

Number of units

Power

Flow

lift

Intake

Outlet

ML-FBH-100T

100 tons

1880 × 3600 × 3200

1

7.5KW

90000

2 sets

1.5KW

130

5m

DN 100 × 2

DN 100 × 2

ML-FBH-110T

110 tons

1880 × 4600 × 3200

1

7.5KW

103000

2 sets

1.5KW

130

5m

DN 100 × 2

DN 100 × 2

ML-FBH-125T

125 tons

1880 × 4600 × 3200

1

11KW

112000

2 sets

1.5KW

130

5m

DN 100 × 2

DN 100 × 2

ML-FBH-150TL

150 tons

2380 × 4600 × 3200

1

11KW

133000

2 sets

2.2KW

160

5m

DN 125 × 2

DN 125 × 2

ML-FBH-175T

175 tons

2380 × 4600 × 3200

1

15KW

170000

2 sets

3KW

240

5m

DN 125 × 2

DN 125 × 2

ML-FBH-200T

200 tons

2780 × 5400 × 3200

1

15KW

205000

2 sets

3KW

240

5m

DN 125 × 2

DN 125 × 2

ML-FBH-225T

225 tons

2780 × 5400 × 3200

1

18.5KW

220000

2 sets

3KW

240

5m

DN 125 × 2

DN 125 × 2

ML-FBH-250T

250 tons

2980 × 5800 × 3200

1

15KW

220000

2 sets

4KW

360

5m

DN 125 × 2

DN 125 × 2

ML-FBH-275T

275 tons

2980 × 5800 × 3200

1

18.5KW

240000

2 sets

4KW

360

5m

DN 125 × 2

DN 125 × 2

ML-FBH-300T

300 tons

2980 × 5800 × 4200

1

22KW

260000

2 sets

4KW

360

5m

DN 125 × 2

DN 125 × 2

ML-FBH-325T

325 tons

2980 × 5800 × 4500

1

22KW

260000

2 sets

4KW

360

5m

DN 125 × 2

DN 125 × 2

ML-FBH-350T

350 tons

2980 × 5800 × 4800

1

22KW

260000

2 sets

4KW

360

5m

DN 125 × 2

DN 125 × 2

★Note: The unit size and number of coil connections on the sample may vary. The exact dimensions, number of coil connections and piping structure are detailed in the drawings provided by the factory.