Address: North of the intersection of North Ring Road and West Ring Road, Weifang Economic Development Zone, Shandong
ML-FBFH combined flow closed cooling tower
It is suitable for high-temperature fluid cooling or large temperature difference projects, with relatively high energy consumption and large volume. With less maintenance, the mixed flow design of the compound flow closed cooling tower is the most efficient closed cooling tower on the market. In order to protect the process refrigerant from pollution, the composite flow closed cooling tower places the process refrigerant in a clean, fully closed circuit, and combines the functions of the cooling tower and the heat exchanger to provide excellent operation and maintenance performance.
Key words:
Classification:
Compound flow
Tel:
Tel:
ML-FBFH combined flow closed cooling tower
Product Details
It is suitable for high-temperature fluid cooling or large temperature difference projects, with relatively high energy consumption and large volume. With less maintenance, the mixed flow design of the compound flow closed cooling tower is the most efficient closed cooling tower on the market. In order to protect the process refrigerant from pollution, the composite flow closed cooling tower places the process refrigerant in a clean, fully closed circuit, and combines the functions of the cooling tower and the heat exchanger to provide excellent operation and maintenance performance.
The hydraulic head is small and consumes less electricity.
The noise is small and the use occasion is wider.
Water loss is smaller, more economical and more in line with sustainable development.
The water distribution method is reasonable, and the water distribution system with gravity falling naturally is adopted, the water distribution hole is not easy to be blocked, and the water distribution is uniform, which maximizes the performance of the filler.
After the module is combined, the efficiency remains unchanged. The efficiency of the countercurrent column is reduced.
|
Model |
tonnage |
Overall dimension |
Fan parameters |
Spray pump parameters |
Inlet and outlet pipe diameter |
||||||
|
Flow |
Length × width × height |
Number of fans |
Power |
Air volume |
Number of units |
Power |
Flow |
lift |
Intake |
Outlet |
|
|
ML-FBFH-30T |
30 tons |
1520 × 2000 × 2800 |
1 |
1.5KW |
23000 |
1 |
0.75KW |
28 |
5m |
DN 50 × 1 |
DN 50 × 1 |
|
ML-FBFH-40T |
40 tons |
1520 × 2300 × 2800 |
1 |
2.2KW |
28000 |
1 |
0.75KW |
29 |
5m |
DN 65 × 1 |
DN 65 × 1 |
|
ML-FBFH-50T |
50 tons |
1520 × 2300 × 2800 |
2 sets |
1.5KW |
32000 |
1 |
1.1KW |
38 |
5m |
DN 80 × 1 |
DN 80 × 1 |
|
ML-FBFH-60T |
60 tons |
1780 × 2300 × 3000 |
2 sets |
1.1KW |
42000 |
1 |
1.1KW |
45 |
5m |
DN 80 × 1 |
DN 80 × 1 |
|
ML-FBFH-80T |
80 tons |
2380 × 2300 × 3000 |
2 sets |
3KW |
64000 |
1 |
2.2KW |
80 |
5m |
DN 125 × 1 |
DN 125 × 1 |
|
ML-FBFH-100T |
100 tons |
2680 × 2700 × 3000 |
2 sets |
4KW |
80000 |
1 |
3KW |
120 |
5m |
DN 125 × 1 |
DN 125 × 1 |
|
ML-FBFH-150T |
150 tons |
3480 × 2700 × 3200 |
2 sets |
5.5KW |
120000 |
1 |
3KW |
150 |
5m |
DN 100 × 2 |
DN 100 × 2 |
|
ML-FBFH-200T |
200 tons |
4680 × 2700 × 3200 |
2 sets |
5.5KW |
130000 |
1 |
4KW |
180 |
5m |
DN 125 × 2 |
DN 125 × 2 |
|
ML-FBFH-300T |
300 tons |
5180 × 2900 × 4500 |
3 |
5.5KW |
225000 |
1 |
7.5KW |
290 |
5m |
DN 150 × 2 |
DN 150 × 2 |
|
ML-FBFH-400T |
400 tons |
5480 × 3100 × 5000 |
3 |
7.5KW |
270000 |
2 sets |
5.5KW |
476 |
5m |
DN 125 × 4 |
DN 125 × 4 |
|
ML-FBFH-500T |
500 tons |
6880 × 3100 × 5000 |
4 |
7.5KW |
360000 |
2 sets |
7.5KW |
580 |
5m |
DN 125 × 4 |
DN 125 × 4 |
★Note: The unit size and number of coil connections on the sample may vary. The exact dimensions, number of coil connections and piping structure are detailed in the drawings provided by the factory.
Previous
Previous
Compound flow cooling tower
Your advice is our motivation
Related Products
FBN series countercurrent cooling tower type scope of application: working fluid temperature difference is large or high temperature (such as 65-35 ℃), such as melting furnace furnace, sintering furnace, vacuum furnace, air compressor, blast furnace, etc.
Cross-flow closed cooling towers are suitable for medium to large-scale cooling needs, and are especially suitable for applications that need to keep the water clean. They perform well in hot climates because they can use the cooling effect of outside air without requiring large amounts of water. They are usually used to cool hot water or cooling media in large facilities such as factories, power plants, chemical plants, refineries, steel plants, etc.
FBN series countercurrent cooling tower type scope of application: working fluid temperature difference is large or high temperature (such as 65-35 ℃), such as melting furnace furnace, sintering furnace, vacuum furnace, air compressor, blast furnace, etc.